What is EMFOCUS?

š¹ EMFOCUS, as know as ELECTROMAGNETIC FOCUS, the electromagnetic focus shockwave technology is a newer generation technology andĀ discharges high-voltage electricity to the electric coil and to form a powerful pulse electromagnetic field energy. The electromagnetic wave generates a deep shock wave in the water. Its advantage is that the output energy is extremely stable, the focal length is long, and the lifespan of the electromagnetic generator is also long-lasting and stable.
š¹Ā EMFOCUS, commonly usedĀ for sport medicine, othepedic and rehabilitation physiotherapy, the high energy acoustic wave can penetrate deep into body tissue mroe than 65mm. The whole treatment is non-invasive, painless and no down time and after one treatment, you can see the effect on your pain areas without any side effects.
The Features about EMFOCUS

š¹Ā Ā No gel pad
š¹Ā Ā Game-changing and affordable focus shockwave
š¹Ā Ā Wider clinical applications
š¹Ā Ā Well denied, precise focus - perfect for diagnosis and therapy
š¹Ā Ā Wide range of energy settings with a pulse rate of up to 4Ā Hz
š¹Ā Ā 12.1 inch large touch screen
š¹Ā Ā User-friendly software with treatment protocols and preset parameters
š¹Ā Ā Single Handle
š¹Ā Ā Easy-to-operate handle with intensity adjustment buttons
š¹Ā Ā Auto water circulation
š¹Ā Ā Long lasting results
What is Focus Shock WaveĀ Therapy?
š¹Ā Ā Ā Shockwave therapy,Ā also known as Extracorporeal ShockwaveĀ Therapy (ESWT), is an non-invasive treatment that utilitiesĀ high-energy acoustic waves to stimulate your body's natural healingĀ process.Ā
š¹Ā Ā Ā OriginallyĀ developed to treat kidney stones and gallstones, it has been found to be effective in treating musculoskeletal!injuries and chronic pain conditions.
š¹Ā Ā Ā Focus shock wave therapy can provide deeper penetration forĀ deeper tissue than radial waves, focusing its output into moreĀ localised, more profound areas.
š¹Ā Ā Ā EMFOCUS, the electromagnetic focus shockwave is based on theĀ physical principle of electromagnetic induction. Ā It enables veryĀ precise and highly sensitive dosing of the applied shock waveĀ energy. The shock wave source used a special coil to focus theĀ shock waves.
š¹Ā Ā Ā Shock waves are generated in water outside the bodyĀ and then transmitted to the biological tissue.Ā This provides anĀ accurately defined focal zone that can move through the skinĀ without losing power.Ā And the site of the applicator on the skin experiences a minimalĀ impact, limiting the damage to surface skin and underlying softĀ tissues (safer & more comfortable).
š¹Ā Ā Ā EMFOCUS treats at defined points within the body and is furtherĀ adapted depending on the required depth.Ā This accuracy featureĀ makes focus shock wave therapy much better for treating issuesĀ deeper within the body.
š¹Ā Ā Ā EMFOCUS shockwaves have substantially higherĀ pressure amplitudes, characterized by a single,mostly positive pressure pulse followed by aĀ comparatively small tensile wave component(negative pressure pulse).
š¹Ā Ā Ā Emfocus shockwave willĀ produce a pressure peak in the range of 10-100Mega-Pascals (MPa), Compared to the positiveĀ peak pressure of 0.1-1 MPa for a radial pressurewave-100 times the amount of energy.
š¹Ā Ā Ā Furthermore, the time taken for a focused shock-wave to reach that peak, as well as its overall pulseĀ duration, is far shorter than that of a RadialĀ shockwave.Ā It's faster, stronger and comforter.

š¹Ā Ā Focused shockwaves are generated by electromagnetic,Ā and it utilitiesĀ water to generate the shockwaves. It wasĀ noted that shock waves penetrate much better throughĀ water than they do through air.

This is the pressure distribution of shock wave focalĀ zone.
š¹Ā Ā That is the area in which the shockwave producesĀ biological effects.The shock wave treatment area insideĀ the body is not identical with the size of the -6dB focalĀ zone.lt can be larger or smaller.
š¹Ā Ā This definition is based on the assumption that a certainĀ minimum pressure threshold exists below which shockwaves have no or only minimal therapeutic effectiveness.The focal zone is the area of maximum energy intensity.The size of focal zone is basicallyĀ independent of theĀ selected energyĀ level.
š¹Ā Ā By contrast, the size of the treatment zone depends onĀ the selected energyĀ level. Emfocus maximum 100%energy output (energyĀ level at 0.45j/mm2)

Radial Shockwave VS Focus Shockwave Therapy


Focused Shockwave technologies comparation

EMFOCUS Treatment Cnditions
Ā
| š¹Ā Ā Plantar fasciitisĀ Ā Ā Ā Ā Ā | š¹Ā Ā Ā Achilles tendonitisĀ Ā Ā |
| š¹Ā Ā Tennis elbowĀ Ā Ā | š¹Ā Ā Ā Golfer's elbow |
| š¹Ā Ā Rotator cuff tendonitisĀ | š¹Ā Ā Calcifc tendonitis |
| š¹Ā Ā Patellar tendonitisĀ Ā Ā Ā Ā | š¹Ā Ā Hip bursitis |
| š¹Ā Ā Shin splintsĀ Ā Ā Ā | š¹Ā Ā Stress fractures |
| š¹Ā Ā Non-healing woundsĀ Ā Ā | š¹Ā Ā Heel spurs |
| š¹Ā Ā Proximal iliotibial band friction syndromeĀ Ā Ā Ā Ā Ā Ā Ā | š¹Ā Ā Calcifcations |
| š¹Ā Ā Morton's neuromaĀ Ā | š¹Ā Ā Tibial stress syndrome |
| š¹Ā Ā Tendinopathy | š¹Ā Ā Trigger points |
| š¹Ā Ā Bone non-unionsĀ Ā Ā Ā |
Treatment Process

EMFOCUS Intelligent Software





